Here, we present the model dependent on the data of our optical phantoms fabricated and measured in our previous preliminary study. The ambiguity between the modeling and the thermal measurements depend on lack of accurate knowledge of material's thermal properties and some exact parameters of the laser beam. Those parameters were varied in the simulation, to provide an overview of possible parameters' ranges and the magnitude of thermal response.
Our goal is to develop an in vivo method for the non-invasive measurement of cerebral blood flow and CSF circulation by exploiting optical and capacitive sensing techniques simultaneously. We introduce a prototype of a wearable probe that is aimed to be used for long-term brain monitoring purposes, especially focusing on studies of the glymphatic system. In this method, changes in cerebral blood flow, particularly oxy- and deoxyhaemoglobin, are measured simultaneously and analysed with the response gathered by the capacitive sensor in order to distinct the dynamics of the CSF circulation behind the skull. Presented prototype probe is tested by measuring liquid flows inside phantoms mimicking the CSF circulation.
There exist several potential optical measurement techniques to be utilised for the purpose. The most desired method would allow the detection of the drugs without using optical biomarkers as a contrast agent. In this case, for non-invasive sensing of the drug in the brain cortex, the drug should have a reasonably strong optical absorption band somewhere in the range between 600 nm and 1700 nm, and not directly coincident with the strong bands of haemoglobin or water. Alternatively, mid-infrared (MIR) range has the potential for invasive drug monitoring techniques.
In this paper, we report the optical properties of several chemotherapy drugs used in CNS lymphoma therapy, such as rituximabi, cyclophosphamide and etoposide. We measured their transmittance and reflectance spectra in near-infrared (NIR) range, particularly 900 nm − 2500 nm, to be considered when choosing the in vivo monitoring method to be developed. The absorption and scattering coefficients were retrieved from the measurements and applying Beer’s law. For the measurement of the sum of total transmission and reflection in NIR range we used integrating sphere with spektralo to enable calculation of the scattering coefficient.
A series of in-vitro measurements were carried out to assess sufficient accuracy for monitoring of blood parameters. A vast number of blood samples with various hematological parameters, collected from different donors, were measured in order to achieve a statistical significance of results and validation of the methods. Preliminary results indicate the benefits in combination of presented complementary methods and form the basis for development of a multimodal system for rapid and accurate optical determination of selected parameters in whole human blood. Future development of optical systems and multivariate calibration models are planned to extend the number of detected blood parameters and provide a robust quantitative multi-component analysis.
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography