The overall chip size is less than half of a SD card. The spectral resolution is 3~5 nm for the whole spectral range of 350~1100 nm. The first order diffraction efficiency reaches over 70% at the blaze wavelength, which is at 550 nm. The signal-to-noise ratio of the SpectroChip system is 1000:1 with 50 ms integration time. The stray light is about 0.04%. A total solution is ready to be incorporated into any smart phone, wearable devices, and handheld device systems. With the incorporation of our SpectroChip sensors, hundreds to thousands items related to personal healthcare can be added to the worldwide health analysis cloud platform.
We have proposed an analytical 2D model [1] of a thickness gradient function for thin film deposition of a LVF for order sorting of a diffraction grating using an evaporation chamber. The LVF was fabricated and its thickness profile was measured using a probe-type surface analyzer. This study proposes an innovative method for overcoming the low production rates currently associated with LVF fabrication.
Within the 25% - 75% thickness range, the profile distribution exhibits a high degree of linearity, with R2 are greater than or equal to 0.9914 for both the cases. The LVF zone width appears to be a linear function of the mask height h, with R2 are greater than or equal to 0.9982 for all the cases. This indicates that the thickness gradient function is a more accurate model for obtaining the thickness profile of an LVF than any other modeling mentioned in previous published results. This study demonstrates that the developed theoretical 2D model can be used to predict accurately the thin film profile of an LVF.
The effective zone width of the LVF is defined as a thickness range of 25% - 75%, which appears to have high degree of linearity as a function of the mask height, h (mask-to-substrate gap). Thus, these results also confirms that the linear variable area increases as the mask-to-substrate gap increases. Thin film layer structures are constructed to demonstrate the efficacy of the proposed LVF design concept. Transmission spectrum result (wavebands 400nm to 1000nm) for varying mask heights at different positions shows maximum number of wavebands with transmittance (>99.9%). Comparison of both the theoretical and the evaporating results matches satisfactorily.
To design a concave grating for a hyperspectral imaging (HSI) system, it is critical to achieve flat field focusing in both the horizontal and vertical directions on the image sensor. We have developed a generalized automation aberration reduction procedure (ARP) that can be applied in any cases of a concave grating spectrometer.
The concave grating, which has a free-form profile with blaze grating pitch and variable line spacing [3], is fabricated using five-axis CNC machine with nanometer machining precision for hyperspectral imaging. In order to evaluate the performance, an optical system is designed and setup to measure the focused spot size, spectral resolution and diffraction efficiency.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.