Scanners in High-Volume-Manufacturing conditions will experience a large range of reticles that vary in reticle transmission and reticle diffraction characteristics. Especially under full production loads reticles will heat up due to the exposure light-load and as such experience thermo-mechanical deformations. The resulting reticle pattern distortion can be partially translated in a deteriorated overall system overlay. Due to the geometry of the reticle and exposure fields, these reticle thermal effects are in general barrel-shape distortions that can be well corrected with the available set of lens manipulators. Nevertheless node-over-node the residual overlay errors associated with thermo-mechanical reticle deformation needs further reduction since it contributes to the total onproduct overlay performance. To reduce overlay caused by reticle temperature drift, NXT1980Di includes an active cooling mechanism suppressing the reticle temperature changes during exposure significantly. Even though the reticle temperature excursions are well suppressed, residual intra-wafer overlay drift effect can still be observed. Before exposure of a wafer, reticle deformation is measured during reticle align using in-line alignment / image sensors (TIS or PARIS). This is enabled by adding alignment markers around the circumference of the image field on the reticle. The measured reticle deformations are then fed to the system control network and dynamically corrected for by making use of the available manipulators in the scanner and the projection lens. Wafer-by-wafer reticle distortion measurements are performed to accurately capture the transient dynamics present in reticle heating during normal production lots. A new version of Reticle Heating Feed-forward Control (RHC2) is introduced that uses reticle-heating-induced deformation measurements over time and exposure sequence information to calibrate reticle-deformation-predictionmodels. These models are based on thermo-mechanical models that simulate reticle deformation under various exposure conditions and are applied in-line to the exposures to reduce intra-wafer overlay drift effects.
ASML’s 300mm scanner-systems are built on the TWINSCAN (XT/NXT) platform and yield high productivity levels for dry as well as immersion litho-scanners. NXT:1980Di immersion scanners yield productivity levels as high as 275wph while maintaining the overlay accuracy. The NXT:1980Di can be equipped with a new leveling mode that results in a significant reduction of the time that is spent on measuring the wafer focus height map. In the new leveling mode the focus height map is measured employing the full width of the level sensor and thereby minimizing the number of leveling scans. In this paper we describe the implementation of the LIL-method in the TWINSCAN platform design. Here, we report on the focus / leveling performance for both test as well as customer product wafers, and present a productivity outlook on the performance gain for a selected set of exposure use-cases.
Adjustment and control of the illumination pupil asymmetry is relevant for wafer alignment and overlay of lithography tools. Pupil asymmetries can cause a tilt in aerial image (Aerial Image Tilt, or AIT). This AIT, combined with a focus offset, leads to a horizontal image shift. Pupil asymmetries can be related to a shift of the entire illumination pupil (geometrical telecentricity) caused by illuminator misalign. Another type of pupil asymmetry is energetic imbalance (quantified by pupil Center of Gravity, COG). The scanner can show pupil variation across the exposure slit.
In general the COG at the edge of the slit is often worse than in the center part of the slit. Recently, ASML has released the NXT:1980Di that is equipped with an enhanced illuminator to improve pupil COG variation across the slit. In this paper we explore the performance of this scanner system and show that the AIT variation across the slit is also reduced significantly.
As design rule shrinks down, on-product focus control became more important since available depth of focus (DOF) is getting narrower and also required critical dimension uniformity (CDU) becomes tighter. Thus monitoring, control the scanner focus error and reducing the focus control budget of scanner are essential for the production. There are some critical layers which has so narrow DOF margin that hardly be processed on old model scanners. Our study mainly focused on the analysis of the scanner focus control budget of such layers. Among the contributors to the focus budget, inter-field focus uniformity was turned out to be the most dominant. Leveling accuracy and intra-field focus uniformity were also dominant.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.